JTB-201 Concrete Surface Hardener is a water-based inorganic composite liquid with exclusive formula, free of any organic substances. It is developed to improve problems such as dusting, sanding and insufficient strength of various concrete floors.
• Dust & moisture resistant
• Waterproof & stain resistant
• Acid, alkali & oil resistant
• Prevents sanding
• Easy to apply
• Eco-friendly & non-toxic
• Dusting & sanding concrete pavements/floors;
• Dusting & sanding terrazzo floors;
• Dusting & sanding quartz hardwearing floors;
• Dusting & sanding cement self-leveling floors;
• Dusting & sanding cement mortar walls/floors
Substrate preparation: Ensure the substrate is completely dry. Remove dust, sand, gravel, paint, coatings, and other contaminants, then rinse thoroughly with clean water. Application can begin once the surface is dry.
Application: Apply evenly with a roller, working in both horizontal and vertical passes to ensure uniform absorption by the concrete surface. Spray application is also acceptable. Increase the application rate on areas that absorb quickly. Noticeable hardening effect can be observed 24 hours after application.
After application, if no additional surface finishes (such as epoxy floor paint, cement-based self-leveling compound, PVC flooring, etc.) are to be applied, the surface can be put into use once dry.
Packaging Specifications: 20 kg/drum or 50 kg/drum.
Storage Conditions: Store in a cool, dry and well‑ventilated indoor area; frost‑resistant (can be stored below 0 °C).
Shelf Life: 12 months.
The product contains chemical ingredients that can irritate the eyes and skin. Please wear the necessary protective gear during construction. In case of accidental eye contact, flush immediately with plenty of clean water and seek medical attention promptly.
JTB technology group are committed to providing customers in all sectors with valuable products and
solutions that offer convenience and efficiency.
Setting a 40-tonne compressor on its foundation looks simple until you measure the gap: typically 25 to 80 millimetres between the underside of the steel baseplate and the top of the concrete. That gap carries the entire operating load, plus vibration, thermal movement and occas...
READ MOREA base plate sits 25 mm above a concrete foundation, and every tonne that presses, vibrates, or torques the equipment above it will pass through that gap. Fill it with ordinary mortar and the mix dries, shrinks, and pulls away from the steel. Leave it as-cast concrete and the co...
READ MOREA concrete patch usually fails where the new material meets the old one. Unmodified cement-sand mortars shrink as they dry, bond weakly to the prepared substrate, and open a hairline gap that admits water and chlorides — the very corrosion cycle you were trying to stop. Polymer-...
READ MORE